High strength galvanized steel wire rope 1770Mpa, 8x19S+FC
Hoisting wire rope&Lifting cable

High strength galvanized steel wire rope 1770Mpa, 8x19S+FC

Drawing galvanized standard steel wire rope for a wide range of applications such as cargo wheels, hoisting, luffing, mooring, hauling, anchoring, etc. It is also suitable for making wire rope slings for lifting operations.

The best combination of flexibility and wear resistance. Parallel laying structure, long service life.

The structure complies with EN 12385 standard.

    Hositing steel wire rope

    Lifting Wire rope is a vital load-bearing and traction component in lifting machinery. Its main function is to lift, pull, tighten and carry heavy objects.

     

    Features:
    (1) Compaction: -
    (2) Rope core: IWRC
    (3) Strength grade: 1770Mpa/1960Mpa/2160Mpa
    (4) Twist type: Same direction or alternating twist
    (5) Twist direction: RH or LH
    (6) Surface condition: Smooth or galvanized

     

    Advantages:
    (1)Wire rope structure is applicable and stable
    (2)Fully lubricated during production

     

    Applications:
    (1)Engineering crane
    (2)Port crane
    (3)Industrial crane
    (4)Offshore crane
    (5)Winch
    (6)Drilling platform

     

    When should crane wire ropes be scrapped?


    When a wire rope meets any of the following conditions, it should be scrapped:
    (1) The number of broken wires in one twist of the wire rope exceeds 10% of the total number of wires.
    (2) The wear of the outer wire exceeds 40% of the original diameter. If it is less than 40%, it can be disassembled and scrapped according to the number of broken wires.
    (3) The number of broken wires in a molten iron or hazardous goods lifting wire rope reaches half the number of broken wires that should be scrapped for general lifting equipment, including the reduction of wire surface corrosion.
    (4) The wire rope diameter is reduced by 7%.
    (5) The entire strand of the wire rope is broken or the fiber core is exposed, and part of the outer wire is extended in a cage-like or hardened state.


    Key points when replacing wire ropes for lifting machinery:
    (1) When replacing old wire ropes, qualified original design models, diameters, nominal tensile strength and wire ropes must be used. If only the same diameter is met and other requirements are lower than the original specifications, the service life of the wire rope will inevitably be affected.
    (2) It is forbidden to use wire ropes without a certificate of conformity. If the wire rope diameter does not conform to the original design, the total breaking force must be equal to the original design. Then the diameter difference should not exceed: 1mm when the original diameter is less than 20mm and 1.5mm when the original diameter exceeds 20mm. If it is too thicker than the original, it will cause the wire rope to rub against each other when it is wound on the drum, increasing wear.

    (3) When replacing or winding the wire rope, be careful not to let the wire rope become knotted. Practice has shown that knotted wire ropes are most likely to wear and break during use. It is forbidden to connect two wire ropes in the lifting mechanism.

    You can learn about our advantages. Wire rope products have various excellent properties and are suitable for a range of applications such as heavy lifting and supporting suspension bridges. If you need wire rope solutions, please feel free to contact us.

     

    港口起重 场景图

    8x19S+FC Specification

    钢丝绳
    公称直径
    Nominal rope
    diameter
    参考重量
    Approx.weight
    钢丝绳最小破断拉力 Minimum breaking load
    双强度 Dual tensile,MPa 单强度 Single tensile,MPa
    1320/1770
    1320/1620
    1370/1770 1570/1770
    1620/1770
    1570 1620 1770
    mm kg/100m kN kN kN kN kN kN
    6.3 13.5 16.4 17.4 19.1 18.3 18.8 20.6
    8 21.8 26.5 28.1 30.8 29.4 30.4 33.2
    9 27.5 - 35.6 38.9 37.3 - 42.0
    9.5 30.7 37.3 39.7 43.6 41.5 42.8 46.8
    10 34.0 41.3 44.0 48.1 46.0 47.5 51.9
    11 41.1 50.0 53.2 58.1 55.7 57.4 62.8
    12 49.0 59.5 63.3 69.2 66.2 68.4 74.7
    12.7 54.8 66.6 70.9 77.5 74.2 76.6 83.6
    13 57.5 69.8 74.3 81.2 77.7 80.2 87.6
    14 66.6 81.0 86.1 94.2 90.2 93.0 102
    14.3 69.5 - - 98.3 - - -
    15 76.5 - 98.9 108 104 - 117
    16 87.0 106 113 123 118 122 133
    17.5 104 - - 147 - - -
    18 110 134 142 156 149 154 168
    19 123 149 159 173 166 171 187
    20 136 165 176 192 184 190 207
    20.6 144 - - 204 - - -
    22 165 200 213 233 223 230 251

     

     

    Technical data:

     

    Steel wire rope Ø(allowable tolerance)
    Zero load: With load (10% of Fmin):
    The maximum value is 3% < 10mm The minimum value is -1%.
    The maximum value is 2%, which is greater than 10mm. The minimum value is -1% > 10mm